Datasafe 12hx400-fr battery specs

WebEnerSys DataSafe 12HX400-FR valve regulated lead acid batteries have been designed to offer superior solutions for the Information Technology and Uninterruptible Power Supply markets. DataSafe 12HX400-FR … WebEnerSys DataSafe HX 12HX205 Nominal Voltage: 12 WPC (watts per cell) for 15 min. to 1.67 VPC at @ 25°C: 204 Short Circuit Current (A): 2,775 Max Discharge Current: 439 Internal Resistance (mΩ): 5 Dimensions (inches): 13.3 x 6.8 x 8.3 Weight: 43 lbs Designed specifically for UPS applications

DATASAFE HX TOP TERMINATED BATTERIES

WebThe DataSafe HX 12HX505 is one of the most powerful batteries in EnerSys’ HX line. It demonstrates minimal gas evolution and is well-suited for low-ventilation, high-rate applications and vital systems. The HX 12HX505, of high-performance classification, meets UL safety standards and is International Air Transport Authority (IATA) approved. WebEnerSys is committed to putting its customers first by showcasing the Company’s latest solutions to empower their operational success in an changing world in Hall 10, Stand B09 at LogiMAT 2024. From traditional flooded lead acid to advanced Thin Plate Pure Lead (TPPL) and Lithium-ion battery technology as well as the latest charging systems ... simpson coaches aberdeen https://cherylbastowdesign.com

HRL12390W - 12 Volt 100Ah - Battery Store

WebBattery Terminal Type: SAE: Manufacturer Part Number: 6TMF: BCI Group Size: BCI No. 6T: Sub Brand: Commercial: VMRS Code: 032001001: Cranking Amperage: 120 A: Cold … WebENERSYS DATASAFE® 12HX400-FR BATTERIES. Power Storage Solutions is a premier platinum stocking Distributor for the Datasafe 12HX400 batteries. We maintain the batteries in a climate controlled … Web100% depth of discharge: 250 cycles 50% depth of discharge: 550 cycles 30% depth of discharge: 1200 cycles Charge retention (shelf life) at 68°F (20°C): 1 month 97% 3 months 91% 6 months 85% Operating temperature range: Charge 5°F to 122°F: (-15°C to 50°C) Discharge -4°F to 140°F (-20°C to 60°C) Standard housing material: simpson cnw5/8

EnerSys DataSafe 12HX400FR Battery - Cogenient

Category:12HX505-FR EnerSys Data Safe Power Storage Solutions

Tags:Datasafe 12hx400-fr battery specs

Datasafe 12hx400-fr battery specs

EnerSys

WebDataSafe 12HX1000F-FR Battery Systems Range Summary. Product Literature. 08/2024. EN Download 05/2012. DataSafe 12HX680F-FR Front Terminal Battery Range Summary ... DataSafe HX 16V Front Terminal Battery Performance Specs. Product Specifications. … WebBattery Performance Specifications Telecommunications. Publication No: US-HXTEL-PS-001 - September 2014 ... 12HX400 12 94 381 8.3 211 6.8 173 13.3 338 80.0 36.3 4225 670 3.0 ... Enersys 12HX205 DataSafe Battery Datasheet Created Date:

Datasafe 12hx400-fr battery specs

Did you know?

WebEnerSys Datasafe 12HX400 / 12HX400FR: 12HX400 FR - Stock Item - Contact Us for Quote UPS High Rate Battery, Lead Calcium AGM, ABS case, 12V with (2) M6 Brass Threaded Insert terminals [381 WPC @15 min to 1.67vpc],[94Ah (c8)] 13.3"L x 6.8"W x 8.3"H (max ht), 80 Lbs EnerSys Datasafe 12HX500 / 12HX500FR: 12HX500 FR - Stock … WebThe Enersys 12HX400 Datasafe Battery is made up of positively and negatively charged lead-calcium-tin alloy plate grids, as well as high-performance, brass-threaded terminals (fasten and bolt) and brass-threaded receptacle. ... Specifications Downloads Reviews (0) ... Enersys 12XE1150F-FR DataSafe Battery $ 781.00 Add to cart; Enersys 12HX505 ...

Web12HX300-FR Specifications Voltage: 12 volt, 70AH Terminal Type: Threaded Receptacle Normal operating temperature range -22F/-30C to 122F/50C Float charging voltage 2.25 – 2.28 Volts per cell at 77F/25C Charging current – can be safely recharged at high current rates Flame retardant case and cover meet UL 1778 12HX300-FR Construction WebVoltage: 12 volts, 82 AH Terminal Type: Threaded Receptacle Normal operating temperature range -22F/-30C to 122F/50C Float charging voltage 2.25 – 2.28 Volts per cell at 77F/25C Dimensions: Length – 11.8″ Width – 6.8″ Height – 18.4″ Weight: 71.0 pounds Key Features AGM separators – the electrolyte is completely absorbed into the separator

WebThe DataSafe 12HX400-FR battery is a part of the EnerSys HX range of valve regulated lead acid (VRLA) batteries. EnerSys incorporates specific design features for superior … WebEnersys Datasafe® 12HX400-FR 400W Replacement Battery - 12V 94Ah Sealed Lead Acid Rechargeable (Flame Retardant) Dimensions: 13.30"L x 6.80"W x 8.30"H …

WebDesign life of 10 years. Flame retardant case and cover to meet UL1778. EnerSys Datasafe 12HX300-FR batteries are also known as HX300, HX300-12FR, 12HX300. Chemistry: …

Webbattery room is not necessary It is recommended that DataSafe ® HX+ batteries are installed on their base Recommended float charge voltage: 2.280Vpc at 68°F (20°C) 2.265Vpc at 77°F (25°C) Up to two year shelf life Reduced maintenance: no water addition required Operating temperature range: -4°F (-20°C) to 113°F (45°C) Standards razer huntsman mini cenaWebDataSafe 12HX1000F-FR Features. Smaller footprint per kilowatt vs. top terminated 12V batteries. Normal operating temperature range -22°F (-30°C) to 122°F (50°C) Float … razer huntsman mini actuation timeWebEnerSys DataSafe 12HX205 General Specifications: Nominal Voltage: 12V. Nominal Ah: 44 (8 Hr Rate to 1.75 volts/cell end voltage at 77°F (25°C)) Watts/Cell: 205 (@ 15 minute rate to volts/cell 1.67 volts/cell end vlotage at 77°F (25°C)) Overall Height: 8.1 inches, 206 millimeters. Width: 5.5 inches, 140 millimeters. simpson co ky road mapWebDataSafe HX batteries are maintenance free, sealed, lead acid batteries and need no water addition. These batteries are equipped with self-resealing, ... 12HX400 24.0 4.2 12HX505 30.0 5.0 12HX540 31.0 5.0 6HX800 50.0 8.5 Table 1. EnerSys 2366 Bernville Road Reading, PA 19605 USA Tel: +1-610-208-1991 razer huntsman mini change colorsWeb•Normal operating temperature range -4°F (-20°C) to 122°F (50°C) •Float charging voltage 2.25 - 2.28 Volts per cell at 77°F (25°C) •Charging current DataSafe®HX top terminated batteries can be safely recharged at high current rates. razer huntsman mini carrying caseWebHX400 by Enersys battery sales support call (888) 330-2538. Power Pros provides expert sales, super low prices, and quantity discounts. ... 12HX400-FR . Shipping: Freight - Call 888-330-2538 for Rates. Qty Price (per unit) 1 - 7 ... enersys-datasafe-hx-batteries-brochure.pdf (2.0 MB) Description; Specifications; razer huntsman mini blackWebFrance (FR) Germany (DE) Ireland (EN ... Request Tech Specs. DC4. Washington DC IBX® Data Center Thank you for your interest. The document is now [[ready for … razer huntsman mini 60% reviews